For Sale TOPCON TRC-NW8 Fundus Camera

  • Condition : Refurbished
  • Qty. Available : 1
  • In Stock : Yes
  • Date : May 15, 2024
  • Listing # : 2256073
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #2256073

  • Condition: Refurbished
  • Brand: TOPCON
  • Type: Fundus Camera
  • Model: TRC-NW8
  • MPN: TRC-NW8
Topcon TRC-NW8 Non-Mydriatic System

Included are the following items:

• Topcon TRC-NW8 Non-Mydriatic Fundus Camera
• Nikon D90 Digital Camera
• Computer, Monitor, Key Board and Mouse
• Topcon IMAGEnet Software

The TRC-NW8 IMAGEnet High Resolution Non-Mydriatic Capture System (Telemedicine Capable) combines IMAGEnet Lite, the recognized standard in fundus imaging telemedicine software, with the Topcon TRC-NW8 automated non-mydriatic retinal camera to provide an easy to use telemedicine color fundus screening package.

True Optical Red Free Photography:
Topcon has developed an innovative feature on its TRC-NW8: True Optical red free capability with an actual red free filter. This feature allows for high resolution red-free image acquisition that is clearer than digitally enhanced images from color-only image systems.

Auto Small Pupil Detection:
A common problem is patients with small pupils and when mydriatic drops cannot be used the “small Pupil” (min 3.3mm) option within the TRC-NW8 allows you to still be able to get a shot.

Quality of Image is Crucial as well as durability:
With these important requirements Topcon did not hesitate in deciding in which manufacture it would use for its camera supplier. Nikon probably has the largest reputation when it comes to digital SLR cameras and is used by most of the worlds’ press for a very good reason. Therefore you have no need to worry that your TRC-NW8 will ever be compromised by the digital SLR in terms of quality of the image or durability.

Lower Flash Intensity:
Topcon has always endeavored to keep flash levels as low as possible while at the same time ensuring that good exposure images are achieved. The TRC-NW8 is no exception here, but with greater control of the CCD Camera, optimum exposure can be achieved each and every time.

Aesthetic Design:
In designing the new TRC-NW8 a lot of attention has been spent on the general appearance of the unit with the finest finish and also on the ergonomics. What was clear when you sit down at the camera is how logical everything is and not cluttered by many different cables. The TRC-NW8 has a unique way of eliminating connecting cables and gives the operator a clutter free environment.

Fixation Target:
In line with the requirements for Diabetic screening when the fixation target mode is set at DCF (“D” is for center of the optic disc, “C” is for the central Macula and “F” is for center of Fovea), the internal fixation will move one by one in the proper position that can be helpful in diagnosis such as glaucoma and diabetes.

So Simple To Use:
Easy Alignment, Auto Focus and Auto Shoot:
Alignment could not be simpler with the New TRC-NW8. Crucially the operator is still in control however with the very latest in alignment aids the process of getting a sharp focused image time after time could not be easier.

Auto focus:
This is a new feature of the TRC-NW8 which allows the operator to choose to have Auto Focus facility. This can be great help when trying to photograph difficult subjects or patients with high degree of accommodation. Auto Focus allows for a sharp image every time.
Auto Shoot:

The TRC-NW8 has the option for Auto Shoot which is of great benefit to the operator as if monitors when all parameters are correct and takes the picture. This rapidly speeds up the capture process and is of great benefit when photographing patients who have problems fixating.

Specifications:

• Angle of Coverage - 45 degrees
• Working Distance - 40.7 mm
• Pupil Size – 4.0 mm or Larger OR 3.3mm or more the small pupil diaphragm is used
• Auxiliary Functions - Auto Focus
• Internal Fixation Target – Center / Periphery, Right/Left Eye Auto detection and Optional position presetting function
• Dimensions: 272mm W X 505mm D X 530mm H
• Weight: 24.5 KG
• Power Source: 50/60Hz, Voltage AC110