(1) PRE-OWNED AND IN VERY GOOD CONDITION
TOPCON TRC-NW6S NON-MYDRIATIC RETINAL CAMERA SYSTEM
*This Unit Has Been Inspected AND Tested By A Professional Optometry Equipment Technician.
It Is Ready To Go To Work In Your Office Or Clinic Today!!*
Warranty: 30-Day Warranty On The Retinal Camera
-Although the pics don't show the Nikon D70s camera, it does include it-
THIS OFFER INCLUDES:
(1) TOPCON TRC-NW6S NON-MYDRIATIC RETINAL CAMERA
(1) NIKON D70s CAMERA (DOESN'T INCLUDE CAMERA ACCESSORIES)
(1) ADAPTER
*THIS OFFER DOES NOT INCLUDE ANY DIGITAL IMAGING CAPTURE SOFTWARE OR A TABLE/DESK
*THIS OFFER DOES NOT INCLUDE THE EXTERNAL FIXATION LAMP EVEN THOUGH ONE IS PICTURED WITH THIS UNIT.
*THIS OFFER IS FOR (1) TRC-NW6S UNIT, BUT THERE ARE A TOTAL OF (3) TRC-NW6S UNITS IN STOCK
TOPCON TRC-NW6S NON-MYDRIATIC RETINAL CAMERA
In this age of rapid advances in digital and electronic technology, Topcon is ready to take a lead with the non-mydriatic retinal camera, the TRC-NW6S, in combination with a capture imaging system. The integrated system connected to a highly sensitive digital camera and capture software, gives clear images and makes diagnosis faster and more reliable. With the TRC-NW6S and capture software, panoramic images of the retina including peripheral area are available by using easy semi-automatic guidance of peripheral fixation. The TRC-NW6S is just a beginning and provides a terrific imaging system.
Easy Focus With Split Focus Bars
Wide Range Of Digital Cameras Supported
30 Degree And 45 Degree Angle Available
Small Pupil Capability Down To 3.7 mm
Easy Creation Of Panoramic Overview With Optional Mosaic Module
The TRC-NW6S can be used in various combinations with the capture software. It can be connected to a highly sensitive CCD camera or digital photocamera in combination with capture software that gives clear images and make diagnosis faster and more reliable. With the TRC-NW6S and capture software, panoramic images of the retina including peripheral area can be made by using easy, semi-automatic guidance of peripheral fixation.
The TRC-NW6S Non-Mydriatic Retinal Camera is the ideal instrument for the growing market in Telemedicine and Diabetic Screening.
The Camera features (8) peripheral fixation points as well as a built-in standard central fixation point, which provide fixed, reproducible fields for use in various study protocols.
The main optical system in the TRC-NW6S incorporates a dual magnification mechanism to allow for digital pictures of either 45 degree or 30 degree fields.
To assist in capturing multiple images using today's advanced digital technology, the camera incorporates (9) flash levels to choose from. This gives the user greater flexibility for capturing all patient images with the most effective level of illumination for each image.
-Easy Alignment
Alignment is easily accomplished by overlapping the two bright spots on the monitor, assuring fast and precise operation. Because the alignment spot is always in the monitor view, the operation is easy and reliable.
-Easy Focusing
Focusing is easily accomplished by aligning the split lines within the focusing bar. For better monitor viewing, the focusing bar may be turned on or off.
-New Ergonomic Design
A totally new design makes the TRC-NW6S compact and ergonomic. The instrument controls, viewing monitor and patients are all in direct alignment for easy access, making it easy to obtain excellent retinal images.
-Auto Flash Intensity
When the angle of coverage is changed by the user, the existing flash setting will be automatically corrected. If required, a manual setting of up to (9) steps is also possible.
-Illuminated Operation Panel
An illuminated operation panel makes operation easy in dim light settings.
-Electric Chinrest Movement For Operational Ease
The control buttons for the electrical elevation of the chinrest are conveniently located next to the joystick for quick operation during photography.
-Small Pupil Capability
It is possible to photograph through a pupil as small as 3.7mm by using the 30 degree angle of coverage.
SPECIFICATIONS
Angle of coverage 45° 30°
Pupil diameter for photography 45° 4.0mmφ or more, 30° 3.7mmφ or more
Patient diopter correction range Without correction lens: -13D to +12D (where split lines are used)
With minus correction lens: -12D to -33D
With plus correction lens: +9D to +40D
Peripheral fixation Internal 8 points
Flash Intensity Automatically changed corresponding to the angle of 45° and 30° Manual setting in 9 steps is also available
Data picturing Simultaneously name plate imaging
Data filing system Data (R/L, angle and 8 fixed position) output to IMAGEnet™ Lite is available
Power source Frequency: 50/60Hz
Voltage: AC110, 120, 230, 240V selectable
Power source Body: 24.5kg, TV relay lens: 1.0kg
Power consumption 400VA (Maximum), 100VA (Normal)
*This Unit Has Been Inspected AND Tested By A Professional Optometry Equipment Technician.
It Is Ready To Go To Work In Your Office Or Clinic Today!!*
Warranty: 30-Day Warranty On The Retinal Camera
*ADDITIONAL SHIPPING COST OF $595 WITHIN THE CONTINENTAL USA INCLUDES PROFESSIONAL PACKING, CRATING, LTL SHIPPING AND INSURANCE*
*PLEASE NOTE: THIS OFFER DOES NOT INCLUDE ANY TABLE/DESK
Return Policy
Items are sold as-is with no returns or refunds available unless explicitly stated.