spacer
Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527
Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527 Listing 3595527

For Sale 3M SARNS 11160 Hypothermia Unit

  • Asking Price :$499.00 USD [convert]
  • Condition : Used - Good
  • Qty. Available : 4
  • In Stock : Yes
  • Date : May 12, 2024
  • Listing # : 3595527
  • credit-card
  • credit-card
  • credit-card
  • credit-card
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #3595527

  • Condition: Used - Good
  • Brand: 3M SARNS
  • Type: Hypothermia Unit
  • Model: 11160
  • MPN: 1731
MPN: 1731
br vocab="" typeof="Product"> 3M SARNS 11160 Dual Heater Cooler Heart & Lung Surgical Perfusion System. This unit has been used previously. This unit may have some signs of cosmetic wear to include the lid is different not the original (See Pictures) However this will not effect the overall functioning of unit. This unit works good. Guaranteed not to be D.O.A

3M SARNS 11160 Dual Heater Cooler Heart & Lung Surgical Perfusion System

3M SARNS 11160 Dual Heater Cooler Heart & Lung Surgical Perfusion System

Click images to enlarge



Description

Description

This machine is part of a larger Heart Lung Perfusion System. This unit has been used previously. This unit may have some signs of cosmetic wear to include the lid is different not the oringial (See Pictures) However this will not effect the overall functioning of unit. This unit works good. I have tested the operation and it works just fine in both heating and cooling modes. I guarantee it will not be DOA. Shows two meter's one has 011293 Total hours the other meter shows 07551. I have two unit's available. There is a picture of the second unit at the end of my pictures

Comes with the Sarns heating cooling unit, clear reservoir lid and two connecting fittings. There are no hoses with this unit. Uses ice and water in the reservoir for cooling and has an internal heater for heating.


Specifics

3M Sarns Heater Cooler Unit
Model: 11160
Serial No: 1731
Hours of use: 011293 totalhours
Second Meter "07551"
4 Cooling Modes (2 Celsius Ambient)
4 Heat Modes (30, 38, 40, 42 Celsius
Re-circulating only Mode
Temperature gauge (0 Celsius 50 Celsius)
Large Ice/Water Reservoir w/ lid
Overheat Indicator
Override Button
3 & 15 Amp circuit breakers for pump & Heater
Hospital grad cord (15 feet long)
4 Large locking wheels.

Manufacturer's Description



The Sarns Dual Cooler-Heater is a self-contained unit for supplying cold and warm water to heat exchangers during open heart surgery. It supplies water at a rate of up to 6.5 gallons per minute (25 liters per minute) at zero head, and will provide a maximum pressure output of 11 pounds per square inch (76,000-pascals). The Sarns TM Dual Cooler-Heater can be used with heat exchangers capable of accepting these flows and pressures.

Condition & Testing



Very decent cosmetic condition and Good tested working condition. 3M SARNS 11160 Dual Heater Cooler Heart & Lung Surgical Perfusion System. This unit has been used previously. This unit may have some signs of cosmetic wear to include the lid is different not the original (See Pictures) However this will not effect the overall functioning of unit. This unit works good. Guaranteed not to be D.O.A Hour meter is reading 011293 hours. The other meter states: 07551. I tested by filling the reservoir with ice/water and attached the hoses to a heat exchanger. This unit quickly changed from the warm and cold temperatures at the heat exchanger within seconds of changing the settings. The pump is really strong. The thermostat is working properly. There are no leaks. The power cord are good.

Age

Unknown

Dimensions

15.5" wide x 26" long x 38 3/4"tall

Warranty

I stand behind everything I sell and for 30 days I guarantee this Sarns Dual Cooler- Heateris exact to the description and pictures I have provided here or return it for a refund

Shipping

This unit weighs 109lbs and will require freight shipping.
Palletweight is 179lbs
Pallet dimensions are 35" x 26" x 37"
NMFC is 133-300 Machine System NOI
Freight Class is 150


To give you some idea it will cost approximately $ 197.13 for west coast shipping and approximately $ 395.71 for east coast shipping.

Residential delivery, limited truck access, lift gate service and inside delivery does cost extra. Contact me with your shipping address for an exact quote.

Pickup is always welcome. located in Coolidge Arizona which is 40 miles SE of Phoenix Az near I-10

All other international buyers must contact me prior to purchasing for a shipping quote.

"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not buy this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."

Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment.. The purchaser, indicates their acknowledgment of, and agreement to the terms of this disclaimer. There are no warranties which extend beyond the description on the face hereof. This item has been cleaned and handled in accordance with the manufacturer's instructions..

Return Policy

Seller Information
Budget Medical
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: